检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周荣玲[1] 陈谦[1] 鞠平[1] 张正利[1] 张浩[1]
机构地区:[1]河海大学能源与电气学院,江苏南京211100
出 处:《江苏电机工程》2015年第6期70-73,81,共5页Jiangsu Electrical Engineering
基 金:国家自然科学基金(51377046;51190121);国家电网公司大电网重大专项资助项目课题:(SGCC-MPLG001(001-031)-2012)
摘 要:含有特殊负荷的大型厂矿局部电网振荡问题时有发生。针对某钢铁企业存在的实际振荡问题,初步分析事故原因,并仿真分析冲击负荷相关因素及企业内部发电机组励磁方式对该电网振荡的影响。结果表明,特殊负荷的位置、冲击幅度及企业内部发电机组励磁方式对局部电网振荡的影响较显著。负荷冲击幅度越大,越易引发振荡;冲击负荷与发电机组电气距离越近,越易引发振荡;发电机组选用恒功率因数励磁方式时,容易引发振荡。仿真结果验证了理论分析结论。根据仿真分析结果,建议厂矿企业局部电网内部发电机组选用恒电压励磁方式;加强局部电网与大电网的电气联系;同时合理布局企业内部的冲击负荷。The local oscillation occurs occasionally in the electric network of large-sized mine. This paper focuses on the oscillation problem in a steel enterprise with a mass of special loads. The possible reasons of the local oscillation is analyzed firstly, and then the simulation considering the mentioned reasons including the impact characters of special load, the excitation mode of local generators, etc. are implemented. It is manifested that the changes of impact load, the location of impact load and the excitation mode of a local generator may significantly affect the oscillation in the small grid. Moreover,the larger the change of impact load is, the larger possibility of the oscillation will be, and the closer the distance between the impact load and generators is, the more significant the oscillation will be. If the exciter of local generator is operated in the constant power factor mode, the generator tends to oscillate more easily than in other modes. The simulation results suggest that the constant voltage mode is a good choice for the exciting regulator, connecting the local grid to the outer power grid improves its reliability, and the impact loads should be reasonably distributed.
分 类 号:TM714[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.63