机构地区:[1]台州市建设工程质量检测中心,浙江台州318000
出 处:《工程质量》2015年第12期9-11,共3页Construction Quality
摘 要:主要依据《建筑外窗气密、水密、抗风压性能现场检测方法》(JG/T 211-2007)、《建筑外门窗气密、水密、抗风压性能分级及检测方法》(GB/T 7106-2008)、《居住建筑节能检测标准》(JG/T 132-2009)三本标准中的内容,结合工程检测实际和经验,提出如何更加科学、快捷、准确地检测工程现场建筑节能外窗的气密性、水密性。This article main basis on the content of the three Standard "Field test method of air permeability,watertightness,wind load resistance performance for exterior windows""JG/T 211-2007" and "Graduations and test methods of air permeability,watertightness,wind load resistance performance for building external windows and doors""GB/T7106-2008" and "Standard for energy test of residential buildings""JG/T132-2009",combined with engineering testing and actual experience,put forward how to test the exterior windows for the building energy efficiency in the engineering field more scientific,efficient and accurate.
分 类 号:TU712[建筑科学—建筑技术科学]