A Fiber Optic Sensor for Determination of 2,4-dichlorophenol based on Iron(Ⅱ) Phthalocyanine Catalysis  被引量:2

A Fiber Optic Sensor for Determination of 2,4-dichlorophenol based on Iron(Ⅱ) Phthalocyanine Catalysis

在线阅读下载全文

作  者:王永红 TONG Yilin 黄俊 LI Kun LIU Huichao DING Liyun LI Mingtian 

机构地区:[1]Wuhan University of Technology Hospital [2]National Engineering Laboratory for Fiber Optic Sensing Technology, Wuhan University of Technology [3]Mechanical and Electrical Engineering College, Hankou University [4]College of Materials and Chemical Engineering, Sichuan University of Science and Engineering

出  处:《Journal of Wuhan University of Technology(Materials Science)》2015年第6期1317-1320,共4页武汉理工大学学报(材料科学英文版)

基  金:Funded by the National Natural Science Foundation of China(Nos.61377092 and 51303115)

摘  要:A new fi ber optic sensor based on the oxidation of 2,4-dichlorophenol(DCP) catalyzed by iron(II) phthalocyanine(Fe(II)Pc) was developed for the determination of DCP. The optical oxygen sensing fi lm containing fl uorescence indicator Ru(bpy)3Cl2 was used to detect the consumption of oxygen in solution. Moreover, a lock-in amplifier was used to determine the lifetime of the sensor head by detecting its phase delay change. The results reveal that the sensor has a linear detection range of 1.0×10^-6- 9.0×10^-5 mol/L and a response time of 5 min. The sensor also has high selectivity, good repeatability and stability. It can be used effectively to determine DCP concentration in real samples.A new fi ber optic sensor based on the oxidation of 2,4-dichlorophenol(DCP) catalyzed by iron(II) phthalocyanine(Fe(II)Pc) was developed for the determination of DCP. The optical oxygen sensing fi lm containing fl uorescence indicator Ru(bpy)3Cl2 was used to detect the consumption of oxygen in solution. Moreover, a lock-in amplifier was used to determine the lifetime of the sensor head by detecting its phase delay change. The results reveal that the sensor has a linear detection range of 1.0×10^-6- 9.0×10^-5 mol/L and a response time of 5 min. The sensor also has high selectivity, good repeatability and stability. It can be used effectively to determine DCP concentration in real samples.

关 键 词:2 4-dichlorophenol iron(II) phthalocyanine phase delay change fiber optic sensor stability 

分 类 号:TP212[自动化与计算机技术—检测技术与自动化装置] O643.32[自动化与计算机技术—控制科学与工程]

 