建筑室内热舒适性随通风条件变化的敏感性研究  被引量:2

Variation Sensitivity of Indoor Thermal Comfort with Ventilation Conditions

在线阅读下载全文

作  者:陈勇[1] 王军[1] 龙恩深[1] 

机构地区:[1]四川大学建筑与环境学院

出  处:《建筑热能通风空调》2015年第3期5-8,共4页Building Energy & Environment

基  金:国家自然科学基金资助项目(51308361);四川省科技计划项目(2014GZ0133)

摘  要:针对典型建筑房间,通过建立物理模型与数学模型并结合CFD模拟方法,研究室内热舒适性随混合通风、置换通风和地板孔板通风三种通风方式的送风条件变化的敏感性,得到人体前后侧0.2m处空气龄、温度场、PMV、PPD分布及变化特征。研究结果将为不同通风方式下合理选择送风条件以改善室内人体热舒适性提供理论指导。As to typical building space, its physical model and mathematic model were established. Moreover,combined with CFD, variation sensitivity of indoor thermal comfort with ventilation conditions was determined for mixing ventilation, displacement ventilation and floor perforated panel ventilation. Meanwhile, distribution and variation characteristics of air of age, temperature, PMV and PPD at 0.2 meter front and back of human body were obtained. The results provides theoretical guidance for reasonably choosing air supply conditions to improving indoor human thermal comfort under different ventilation patterns.