传统金属拉力钉和高分子可吸收螺钉固定不稳定踝关节骨折的比较  被引量:22

Comparison of traditional metal pulling nail and macromolecule absorbable screw fixation in repair of unstable ankle fractures

在线阅读下载全文

作  者:杨宁[1] 窦群立[1] 杨进[1] 

机构地区:[1]陕西中医药大学附属医院骨科,陕西省西安市712000

出  处:《中国组织工程研究》2015年第48期7801-7805,共5页Chinese Journal of Tissue Engineering Research

基  金:陕西省社发攻关项目(2011K12-05-13)~~

摘  要:背景:临床治疗下胫腓联合分离型不稳定踝关节骨折可以采用外科内固定方式,内固定过程中可以选择不同的材料,以往大多使用金属拉力钉,但存在断钉等风险。目的:探讨传统金属拉力钉和高分子可吸收螺钉固定在下胫腓联合分离性不稳定踝关节骨折中的应用效果。方法:回顾性分析陕西中医药大学附属医院2013年2月至2014年2月收治的63例下胫腓联合分离性不稳定踝关节骨折患者的临床资料,均实施外科内固定治疗,按照所使用材料的不同分为金属拉力钉组32例和可吸收螺钉组31例。于腓骨下段外侧做切口对骨折端予以复位,并利用钢板进行固定,并分别利用传统金属拉力钉和高分子可吸收螺钉进行固定。内固定后随访12个月,观察两组的踝关节功能评分(Baird-Jackson)和临床效果以及不良事件发生情况,并进行比较。结果与结论:可吸收螺钉组患者平均下地活动时间和内固定后住院天数均显著少于金属拉力钉组(P<0.05)。两组踝关节功能评分(Baird-Jackson)较固定前均上升,但差异无显著性意义(P>0.05)。可吸收螺钉组治疗优良率显著高于金属拉力钉组(P<0.05)。内固定后随访12个月,金属拉力钉组有1例患者出现螺钉断裂,可吸收螺钉组未出现任何不良事件,2组患者均未出现切口感染等情况。结果证实,利用高分子可吸收螺钉固定治疗下胫腓联合分离性不稳定踝关节骨折可以获得较之传统金属拉力钉更好的应用效果。BACKGROUND:Clinical treatment of tibiofibular syndesmosis separation of unstable ankle fractures can be treated by surgical internal fixation method. The internal fixation process can choose different materials, in the past, most of the operations used metal pul ing nail, but there may be broken nails and other risks. OBJECTIVE:To explore the application effect of traditional metal pul ing nail and macromolecule absorbable screw fixation in tibiofibular syndesmosis separation of unstable ankle fracture. METHODS:The clinical data of 63 patients with tibiofibular syndesmosis separation of unstable ankle fractures who received surgical internal fixation treatment in Affiliated Hospital of Shaanxi University of Chinese Medicine from February 2013 to February 2014 were retrospectively analyzed. Patients were divided into metal pul ing nail group (n=32) and absorbable screw group (n=31) according to the use of different materials. The fracture end was reset by cutting from the outside of the lower section of the fibula. The steel plate was used for fixation. The traditional metal pul screws and macromolecule absorbable screw were used for fixation. During the 12 months of fol ow-up after internal fixation, the ankle function scores of two groups (Baird-Jackson), clinical effect and the incidence of adverse events were observed and compared. RESULTS AND CONCLUSION:The average ambulation time and hospital stay of patients after internal fixation in absorbable screw group were significantly less than those of metal pul ing nail group (P〈0.05). The ankle joint function scores (Baird-Jackson) in these two groups were increased compared with those before surgery, but the difference was not significant (P〉0.05). The excel ent and good rate of patients in absorbable screw group was significantly higher than that in the metal pul ing nail group (P〈0.05). During 12 months of fol ow-up after internal fixation, one patient had screw breakage in metal pul ing nail group. There was no wound

关 键 词:踝关节 骨折 不稳定骨折 内固定 临床研究 组织工程 骨科植入物 关节植入物 下胫腓联合 下胫腓联合分离 金属材料 金属拉力钉 骨钉 可吸收材料 高分子可吸收螺钉 

分 类 号:R318[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象