检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]南昌航空大学无损检测教育部重点实验室,江西南昌330063 [2]Laboratoire de Physicochimie de l'Atmosphere, Universite du Littoral Cote d'Opale Dunkerque 59140, France
出 处:《光谱学与光谱分析》2015年第11期2985-2989,共5页Spectroscopy and Spectral Analysis
基 金:国家自然科学基金项目(41265011,61177096);江西省科技厅对外科技合作计划项目(20132BDH80006);江西省教育厅科学技术研究项目(GJJ14548)资助
摘 要:介绍了基于紫外LED光源的非相干宽带腔增强吸收光谱装置,并将其应用于实际大气中的HONO和NO2浓度的探测。中心波长为365nm的UV-LED出射光被耦合到~1.76m长,由两片高反射率镜片组成的光学谐振腔内,透过腔的光由便携式CCD光谱仪接收。高反射率镜片的反射率由NO2和O2-O2的吸收谱来校正,在353~376nm的测量范围内,最高反射率为0.999 17。在120s的采集时间内,HONO和NO2的探测极限(1σ)分别为0.6和1.8ppbv。将该装置测量的连续56h大气中NO2浓度的变化与配备蓝光转换器的NOx分析仪测量的结果进行比较,线性相关系数R2=0.89,斜率为1.09,截距为3.45。基于该装置探测了实验室大气中的HONO和NO2昼夜浓度变化,24h内的HONO浓度在0~5.3ppbv之间波动,平均浓度为1.8ppbv,NO2浓度变化范围为5~51ppbv,平均浓度为21.9ppbv。We report on the development of an optical instrument based on LED-IBBCEAS for simultaneous measurements of nitrous acid(HONO)and nitrogen dioxide(NO2)in ambient air.The light emitting from the LED centered at 365 nm was directly focused into the cavity formed with two high reflectivity mirrors,separated by a distance of 1.76 m.The light output of the cavity was received with a portable spectrometer.The mirror reflectivity was calibrated by absorption spectra of NO2 and O2-O2.In the spectral range of 353~376nm,the maximum mirror reflectivity was found to be 0.999 17.Detection limits(1σ)of 0.6ppbv for HONO and 1.8ppbv for NO2 were achieved with an acquisition time of 120 s.In order to test the accuracy of measured results by present setup,concentrations of NO2 were recorded during continuous 56 hours and compared with data from a NOX analyzer equipped with a blue light converter.The least-square fit lines give gradients of 1.09 and respective intercepts of 3.45,with a linear correction factor of 0.89.The concentrations of HONO and NO2 in indoor air were monitored,the concentrations of HONO varied from near 0to 5.3ppbv in 24 hours,the averaged concentration was 1.8ppbv,and the concentrations of NO2 varied from 5to 51 ppbv at the same time,the averaged concentration was 21.9ppbv.
关 键 词:光谱技术 非相干宽带腔增强吸收光谱技术 HONO测量技术 NO2测量技术
分 类 号:O33[理学—一般力学与力学基础]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117