作 者:王飞[1] 王耀翔[1] 王国伟[1] 雷勇刚[1] 张建伟[2] 李建刚[2] 梁鹂[2] 李海东[2] 范敏[2]
机构地区:[1]太原理工大学 [2]太原市热力公司
出 处:《暖通空调》2016年第1期92-96,共5页Heating Ventilating & Air Conditioning
摘 要:摘要为使有限元法准确用于直埋供热管道L形弯头的应力计算,直埋敷设了DN800预制保温管实验台,测试了5种供水温度下L形弯头的应变,将实验应变值与有限元解进行对比分析,验证了有限元模型及其边界条件的正确性。这种经过实验验证的有限元法可准确用于小于弹性臂长的DN600~DNl200直埋供热L形弯头的应力计算。In order to verify the accuracy of stress calculation with the finite element method for the L-shaped elbow of directly buried heating pipe, develops a DN800 directly buried heating pipeline experimental rig, and tests the strain of the L-shaped elbow at five different supply water temperatures. Compares the test values with finite element solution. The results show the correctness of the finite element model and the boundary conditions. The finite element method verified by experiment can be applied to the stress calculation of directly buried heating L-shape elbows with the arms shorter than the length of the expansion leg and pipe diameter of DN600 to DN1200.
分 类 号:TU995.3[建筑科学—供热、供燃气、通风及空调工程]