不同分娩方式对盆底功能的影响及电刺激治疗的疗效分析  被引量:23

Efficacy analysis of different delivery modes on female pelvic floor function and therapeutic effect of the biofeedback combined with electrical stimulation on pelvic floor

在线阅读下载全文

作  者:王淑静[1] 邓晓岚[2] 菅莹莹[1] 王瑜[1] 何荣霞[2] 

机构地区:[1]兰州大学,甘肃兰州730000 [2]兰州大学第二医院妇产科,甘肃兰州730000

出  处:《中国计划生育和妇产科》2016年第1期58-64,共7页Chinese Journal of Family Planning & Gynecotokology

摘  要:目的探讨不同分娩方式对女性盆底功能的影响及生物反馈电刺激治疗在盆底功能恢复方面的疗效。方法选取2013年1月至2015年4月兰州大学第二医院妇产科产后6~8周进行复查的初产妇460例的临床资料,根据分娩方式不同分为剖宫产组(204例)、中转剖宫产组(24例)、会阴保护组(59例)、会阴侧切组(163例)和产钳助产组(10例),运用盆底肌电生物反馈仪对5组量化评估盆底不同肌纤维的肌力,对44例肌力较弱者进行生物反馈电刺激治疗后再次进行盆底肌力评估。结果①剖宫产组前静息状态平均肌电值高张型构成比(71.57%)明显高于会阴钡4切组(47.24%),且其高张型平均肌电值(8.54uV)明显高于会阴保护组(6.27uV)、会阴侧切组(6.99uV)和产钳助产组(5.26uV);②剖宫产组后静息状态平均肌电值高张型构成比(72.55%)明显高于其它4组,且其高张型平均肌电值(8.26uV)明显高于会阴保护组(6.65uV)和会阴侧切组(6.76uV);③会阴保护组和会阴侧切组快肌最大肌电值低张型构成比(81.36%、74.23%)明显高于剖宫产组(46.57%),且会阴侧切组低张型平均肌电值(20.68uV)低于剖宫产组(23.44uV);(4)会阴保护组和会阴侧切组混合肌平均肌电值低张型构成比(91.53%、92.64%)明显高于剖宫产组(73.53%),且两组低张型平均肌电值均低于剖宫产组;⑤会阴侧切组慢肌平均肌电值低张型构成比(89.57%)高于剖宫产组(75.98%),且剖宫产组低张型平均肌电值高于其他4组;⑥产钳助产组快肌、混合肌、慢肌低张型平均肌电值明显低于其他4组;⑦快肌、混合肌、慢肌三者各自低张型构成比在生物反馈电刺激治疗后明显降低,三者各自整体平均肌电值在治疗后均明显升高,经比较差异均有统计学意义(P�Objective To analyze the effects of different delivery modes on female pelvic floor function and the significance of biofeedback combined with electrical stimulation on restoring female pelvic floor function. Methods 460 cases of primipara treated at 6 to 8 weeks after delivery in the Department of Gynecology and Obstetrics of Lanzhou University Second Hospital from January 2013 to April 2015 were selected as study objects, and then they were divided into cesarean section group (n = 204), transit cesarean delivery group (n = 24), perineal protection group (n = 59 ), episiotomy group (n = 163 ) and forceps delivery group (n = 10) ; pelvic floor muscle strength was assessed by pelvic floor myoelectricity physiologic instrument in the five groups ; 44 cases of pelvic floor dysfunction underwent the therapy of biofeedback combined with electrical stimulation and pelvic floor muscle strength assessment was performed again. Results (1) The composition ratio of higher type on the former resting state in cesarean section group ( 71.57 % ) was statistically significantly higher than those in episiotomy group(47.24 % )and the averaged electromyogram(AEMG) of higher type in cesarean section group( 8.54 uV)was statistically significantly higher than those in perineal protection group(6. 27 uV), episiotomy group(6.99 uV)and forceps delivery group(5.26 uV) ; (2) the composition ratio of higher type on the latter resting state in cesarean section group (72. 55 % )was statistically significantly higher than those in the rest of groups and the AEMG of higher type in cesarean section group(8. 26 uV)was statistically significantly higher than those in perineal protection group(6. 65 uV)and episiotomy group(6. 76 uV); (3) the composition ratios of lower type on the fast pelvic floor muscle fiber in perineal protection group( 81.36 % ) and episiotomy group (74. 23 % ) were statistically significantly higher than that in cesarean section group (46. 5

关 键 词:分娩方式 盆底功能 肌纤维 生物反馈 电刺激 

分 类 号:R714.142[医药卫生—妇产科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象