离子色谱法测定骨瓜提取物注射液中糖的含量  被引量:2

Content Determination of Carbohydrates in Osseous and Cucumis Extract Injection by Ion Chromatography

在线阅读下载全文

作  者:张伟[1] 张彤[1] 任连杰[1] 吕雯[1] 韩春霞 周长明[1] 

机构地区:[1]北京市药品检验所,北京100035 [2]赛默飞世尔科技(中国)有限公司,北京100007

出  处:《中国药房》2016年第3期386-389,共4页China Pharmacy

摘  要:目的:建立测定骨瓜提取物注射液中糖含量的方法。方法:采用离子色谱法。色谱柱为Dionex Carbo Pac PA20,流动相为水-1 mol/L醋酸钠溶液-250 mmol/L氢氧化钠溶液(梯度洗脱),流速为0.45 ml/min,柱温为35℃,进样量为10μl,检测器为电化学分析检测器。结果:半乳糖、葡萄糖、甘露糖、蔗糖、果糖检测质量浓度线性范围均为0.5-10.0μg/ml(r〉0.9980);精密度、稳定性、重复性试验的RSD〈2%;各组分加样回收率为94.8%-99.1%,RSD=0.52%-0.89%(n=9)。结论:该方法简单、快速、准确,可用于骨瓜提取物注射液中糖的测定。OBJECTIVE: To establish a method for the content determination of carbohydrates in Osseous and cucumis extract injection. METHODS: Ion chromatography was conducted on the column of Dionex CarboPac PA20 with mobile phase of water-1 mol/L Sodium acetate solution-250 mmol/L Sodium hydroxide solution (gradient elution) at flow rate of 0.45 ml/min, column temperature was 35 ℃, and injection volume was 10μl, detector was electrochemical analysis detector. RESULTS: The linear ranges of galactose, glucose, mannose, sucrose and fructose were 0.5-10.0 μg/ml(r〉0.998 0); RSDs of precision, stability and reproducibility tests were lower than 2 % ; recovery was 94.8 %-99.1% (RSD = 0.52 %-0.89 %, n = 9). CONCLUSIONS : The method is simple, fast and accurate, and can be used for the determination of carbohydrates in Osseous and cucumis extract injection.

关 键 词:离子色谱法 骨瓜提取物注射液  

分 类 号:R927.2[医药卫生—药学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象