出  处:《福建建设科技》2016年第1期54-56,88,共4页Fujian Construction Science & Technology

基  金:福建省科技重点项目(编号:2011H0026)资助

摘  要:采用标定热箱法对四种新型的建材型光伏构件的传热系数进行测试,分析影响传热系数不确定度评定的相关因素,对四种光伏构件的传热系数试验结果进行不确定度评定,通过不确定度的评定结果评定标定热箱法仪器的测试精度,分析该方法测试建材型光伏构件传热系数的可行性。Calibration hot box test method was used to test the thermal transmittanee of four kinds of new type building integrated photovoltaie components. The related faetors influencing the uncertainty evaluation of the thermal transmittance were analyzed, and the thermal transmittance test results uncertainties of fuur types of photovoltaie components were evaluated. Through the uncertainty evaluation results to, the test accuracy of calibration hot box instrument was assessed, and the feasibility of using the method to test the thermal transmittance of building integrated photovollaie components was analyzed.

关 键 词:建材型光伏构件 标定热箱法 传热系数测试 不确定度评定 

分 类 号:TU111[建筑科学—建筑理论] TU18

 