检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《临床心身疾病杂志》2016年第1期136-137,共2页Journal of Clinical Psychosomatic Diseases
摘 要:目的探讨不同封管液对经外周留置的中心静脉导管输注20%甘露醇的影响。方法将99例颅内肿瘤患者按人院顺序分为3组,每组33例。A组用肝素钠盐水10ml正压封管;B组用0.9%生理盐水10ml脉冲式冲管,肝素钠盐水10m1正压封管;C组用0.9%生理盐水≥20ml脉冲式冲管,肝素钠盐水10m1正压封管。结果A组导管堵管率为51.5%,B组为24.6%,C组为6.1%。C组导管堵管率显著低于A组、B组(P〈0.05或0.01),B组显著低于A组(P〈0.05)。结论对经外周留置的中心静脉导管置管长期输注20%甘露醇完毕后用≥20ml生理盐水脉冲式冲管,肝素钠盐水正压封管,可有效降低导管堵管率。Objective To explore the influences of different tube sealing solutions on infused 20% mannitol via a peripherally inserted central catheter (PICC). Methods Ninety-nine in-tracranial neoplasms patients were assigned to three groups oI 66 ones eacn according to admission order.Group A was locked using heparin sodium +10 ml normal saline; group B was flushed using 10 ml 0.9% normal saline and locked using heparin sodium +10 ml normal saline; group C was flushed using ~ 20 ml 0.9% normal saline and locked using heparin sodium +10 ml normal saline. Results Catheter obstruc-ting rate was 51.5% in group A, 24.6% B and 6.1% C, that significantly lower in C than in A and B (P〈0.05 or 0.01), so was that in B than in A (P〈0.05). Conclusion PICC flushed using ≥20 ml normal saline after long-term 20% mannitol infusion and locked using heparin sodium + normal saline could effectively lower catheter obstructing rate.
关 键 词:经外周留置的中心静脉导管置管 20%甘露醇 封管方法
正在载入数据...