漏磁式智能检测技术在输气管道上的应用  被引量:2

The Application of Magnescan HR in Gas Transmission Pipeline

在线阅读下载全文

作  者:李勇[1] 陈开明[1] 熊建嘉[1] 付建华[1] 

机构地区:[1]西南油气田分公司

出  处:《油气储运》2002年第8期24-29,共6页Oil & Gas Storage and Transportation

摘  要:分析了达县一卧龙河输气管道达福段管道内、外腐蚀的原因,采用首次引进的国外漏磁式智能检测技术对该段管道进行了检测,通过分析该技术的检测参数、置信度、经济效果评价和存在的缺陷,提出了减缓管道腐蚀的若干建议。Daxian-Wolonghe Gas Transmission Pipeline to transmit wet natural gas (H2S content is approximately 4. 0 g/m3),with a total length of 145 km,located at Sichuan Province,put into operation in 1986. Duo to serious corrosion,leaks were found at 26 locations in the pipeline. To inhibit the corrosion,the Mag-nescan HR technology introduced is used to the corroded pipeline. By means of analysis of inspection parameters, the confidence level, economic evaluation and inability of this technology as well as the suggestions in inhibiting corrosion of the pipeline are put forward.

关 键 词:输气管道 腐蚀 漏磁式智能检测技术 应用 

分 类 号:TE973.6[石油与天然气工程—石油机械设备]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象