基于压水试验的杨村煤矿底板断层带渗流性质研究  被引量:8

Research on Seepage Characteristics of Floor Fault Zone Based on Water Injection Test in Yangcun Coal Mine

在线阅读下载全文

作  者:邵明喜[1] 官云章[2] 曹思文[1] 张鑫[1] 刘近国 吕先阳 孙晓倩[3] 

机构地区:[1]兖州煤业股份有限公司杨村煤矿,山东兖州272118 [2]兖矿集团兖州煤业股份有限公司,山东邹城273500 [3]中国矿业大学资源与地球科学学院,江苏徐州221116

出  处:《矿业安全与环保》2016年第1期73-76,80,共5页Mining Safety & Environmental Protection

摘  要:为研究杨村煤矿底板断层带的渗流性质,采用现场压水试验方法对底板F5断层进行了测试并获取了大量的实测数据,分析结果表明:该断层在原始状态下渗流能力较差,阻渗性较强。对该断层进行了4次压水试验,对比4次压水试验的渗透系数变化曲线可知,重复压水可导致断层带明显渗透破坏,由此造成其导渗性能的进一步增强;F5断层带两段压渗试验压力和流量关系(p—Q)为扩张或冲蚀型,该断层带裂隙发育,裂隙中间有较多充填物,阻渗能力较好。In order to study the seepage characteristics of the floor fault zone in Yangcun Mine, water injection test method was used for the measurement of Fault 5 and a number of measured data were obtained. Analysis results showed that the permeability of this fault was bad and its permeation resistance was relatively strong in the original state. Four water injection tests on this fault were carried out, and from the comparison of the permeability changing curves in four water injection tests it was found out that the repeated water injection can lead failure of the fault zone, which in turn improved its permeability. The relation between test pressure and flow rate(p-Q) of F5 fault was a dilation or erosion type, the fissures in this fault zone developed and many filling materials existed in it, so it has stronger resistance to seepage.

关 键 词:压水试验 煤层底板 断层 渗流性质 渗透系数 

分 类 号:TD163.1[矿业工程—矿山地质测量]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象