微波消解-ICP-MS法测定天舒胶囊中5种重金属元素  被引量:2

Determination of Five Heavy Metals in Tian Shu Capsules by ICP-MS

在线阅读下载全文

作  者:廉源沛[1] 谢达温[1] 李艳静[1] 徐殿红[1] 丁岗[1] 黄文哲[1] 萧伟[1] 

机构地区:[1]江苏康缘药业股份有限公司中药制药过程新技术国家重点实验室,连云港222001

出  处:《药学与临床研究》2016年第1期23-25,共3页Pharmaceutical and Clinical Research

基  金:国家科技部"重大新药创制"项目:偏头痛治疗药物天舒胶囊大品种技术改造(2012ZX09201201-002)

摘  要:目的使用电感耦合等离子体质谱(ICP-MS)仪,建立天舒胶囊中Cu、As、Pb、Cd、Hg 5种重金属元素的测定方法.方法:样品经过微波消解处理后,采用外标法,以ICP-MS进行测定.结果:各元素线性关系良好(r〉0.9990),最低检测限为(0.0014-0.8237)μg·L^-1,回收率为98.4%-114.1%.结论:该方法准确、简便、快速、灵敏,适用于天舒胶囊内容物中重金属的含量测定.Objective: To provide a method for the simultaneous analysis of five heavy metals, including Cu, As, Pb, Cd and Hg, in Tian Shu capsules. Methods: Five heavy metals in Tian Shu capsules were determined by a method of inductivity coupled plasma-mass spectrometry with microwave-assisted digestion.Results: The correlation coefficients were better than 0.999. The method detection limits for all target elements were in the range of(0.0014-0.8237) μg·L-1, and the recoveries ranged in 98.4%-114.1%. Conclusion: This method is accurate, convenient, rapid and highly sensitive and can be applied to determine the five heavy metals, including Cu, As, Pb, Cd and Hg, in Tian Shu capsules.

关 键 词:ICP-MS 微波消解 天舒胶囊 重金属 

分 类 号:R927.2[医药卫生—药学]

 