手术室内镜器械的清洗消毒方法研究  被引量:17

Study on the methods for the cleaning and disinfection of endoscopic equipments in operating rooms

在线阅读下载全文

作  者:傅玉仙[1] 

机构地区:[1]浙江省衢州市常山县人民医院,浙江衢州324200

出  处:《中国消毒学杂志》2016年第1期36-38,共3页Chinese Journal of Disinfection

摘  要:目的研究医院手术室内镜器械的清洗消毒方法及其清洗消毒效果。方法采用细菌定量培养方法,对某医院使用后的内镜器械不同清洗消毒方法的效果进行比较观察。结果传统清洗消毒方法的对照组消化内镜清洗消毒效果合格率为90.2%;观察组内镜清洗工艺中加入了酶洗环节,清洗消毒效果合格率为98.2%。传统清洗消毒方法的对照组无菌内镜附件灭菌效果合格率为92.1%;观察组清洗消毒方法清洗的无菌内镜附件灭菌效果合格率为97.4%。结论内镜清洗消毒在传统方法的基础上,加入酶洗环节可明显提高清洗消毒质量。Objective To study the methods for the cleaning and disinfection of endospcopic equipments in operating rooms. Methods A comparative study was made for the effects of different cleaning and disinfection methods on endoscopic equipments in a certain hospital through the method of quantitative cultivation of bacteria. Results For the control group,the qualification rate for the traditional method of cleaning and sterilization of endoscopic equipments was 90. 2%; for the observation group,because of the adding of enzyme washing,the qualification rate was 98. 2%. For the control group,the qualification rate for the traditional method of sterile endoscopic accessories disinfection was 92. 1%. For the observation group,the qualification rate for the method of cleaning and sterilization of sterile endoscopic accessories sterilization was 97.4%. Conclusion The disinfection effect of traditional method of cleaning and disinfection can be significantly improved through the adding of enzyme washing.

关 键 词:内镜 清洗 消毒 效果检测 

分 类 号:R187.2[医药卫生—流行病学]

 