检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:廖凯[1]
机构地区:[1]中铁第一勘察设计院集团有限公司,西安710043
出 处:《铁道标准设计》2016年第3期152-154,158,共4页Railway Standard Design
摘 要:我国大部分地区地铁车站仅在夏季设置空调系统供冷,冬季不供暖。在运用土壤源热泵系统时,会造成土壤热积累,运行效率逐年下降。冷却塔复合式地源热泵能够在冬季将土壤夏季积累的热量排出,保持土壤冷热负荷相等,从而提高地铁车站空调系统夏季运行能效。通过计算地铁车站夏季空调负荷,对采用复合式地源热泵系统的节能潜力进行分析。结果表明,采用该系统能够有效减少地铁车站空调系统能耗,达到节能效果。Most subway stations in China are provided with cooling in summer and there is no need for heating in winter. The application of ground source heat pump( GSHP) system causes heat accumulation in soil and GSHP efficiency is declined year after year. In winter,the hybrid GSHP with cooling tower can discharge the accumulated heat in soil in summer,keeping equivalence of cooling load and heating load,and improving the efficiency of the air conditioning system in summer. Energy saving potential of hybrid GSHP system in subway is analyzed based on the calculation of subway station cooling load. The results show that hybrid GSHP system can effectively reduce energy consumption of air conditioning in subway station for more energy saving.
分 类 号:U231.4[交通运输工程—道路与铁道工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.147.44.46