检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:袁林光 薛战理[1] 李宏光[1] 李涛[1] 杨鸿儒[1]
机构地区:[1]西安应用光学研究所国防科技工业光学一级计量站,陕西西安710065
出 处:《光学精密工程》2016年第1期59-64,共6页Optics and Precision Engineering
基 金:十二五总装预研项目(No.62201050103)
摘 要:研究了在-60~50℃条件下准确测量材料法向发射率的方法。基于发射率定义建立了材料法向发射率测量模型。为屏蔽环境杂散辐射与大气吸收的影响,利用真空液氮背景通道搭建了低温状态下材料发射率测量装置。测量了氧化铜与高发射率陶瓷两种样品的法向发射率随温度、波长的变化情况。结果表明:两种样品的法向光谱发射率均随波长增加而降低;随温度的升高,氧化铜样品法向积分发射率稳定为0.850±0.012,陶瓷样品的法向积分发射率降低了0.124。最后,实现了低温状态下红外光谱辐射的高精度采集,对低温状态下材料法向光谱发射率测量结果的不确定度进行了评定,得到的结果显示其相对扩展不确定度小于6.0%。The measuring methods for normal emissivities of materials at-60—50 ℃ was explored.To achieve accurate measurement of normal emissivity of materials at temperature range of-60℃to50 ℃,a measurement model of normal emissivity of materials was established based on the emissivity definition.To shield the effects of environment stray radiation and atmospheric absorption,a measurement facility of the materials at low temperature was built by utilizing a vacuum and liquid nitrogen background channel.The normal emissivities of two samples(copper oxide and high emissivity ceramic)were measured by this facility.The results show that normal spectral emissivities of two samples decrease with wavelengths.Moreover,with temperature increasing,the normal integral emissivity of the copper oxide keeps stable at the range of 0.850±0.012 and that of the high emissivity ceramic reduces by 0.124.Finally,the infrared spectral irradiation was acquired in higher precision at a lower temperature condition,the measurement uncertainty of normal spectral emissivities of materials at low temperature was analyzed.The results show that the relative expanded uncertainty is less than 6.0%.
关 键 词:材料发射率测量 低温测量 法向发射率 真空液氮背景通道 测量不确定度
分 类 号:TB302[一般工业技术—材料科学与工程] TN219[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33