Optimization Design and Experiment of the Radio Frequency Transmission Utilized in Video Capsule Endoscope  

Optimization Design and Experiment of the Radio Frequency Transmission Utilized in Video Capsule Endoscope

在线阅读下载全文

作  者:刘刚 颜国正 朱柄全 徐文铭 

机构地区:[1]Institute of Precise Engineering and Intelligent Microsystems,Shanghai Jiaotong University,Shanghai 200240,China

出  处:《Journal of Shanghai Jiaotong university(Science)》2016年第1期1-6,共6页上海交通大学学报(英文版)

基  金:the National Natural Science Foundation of China(No.31170968);the Shanghai Science Committee Foundation(No.09DZ1907400)

摘  要:In view of fuzzy and unstable images received in video capsule endoscopy, and the poor communication effect, an improved radio frequency(RF) transmission circuit module with low power consumption and helix antenna is designed to improve the performance of video transmission and to extend the working time of the capsule. Simulation and analysis of the circuits and antenna with HFSS12 and ADS2011 software are highlighted.Video capsule endoscope prototypes are made and evaluated to verify the feasibility of the proposed design. In vitro tests and animal experiments show that the results of the antenna tests basically meet the simulation, and the power consumption of RF circuit is 15.9 mV. The video capsule endoscope works well with the receiver with multiple receiving antennas, and the working time is more than 9 h. It can realize the wireless transmission of the video data, and images received are clear and stable in comparison with the previous designs.In view of fuzzy and unstable images received in video capsule endoscopy, and the poor communication effect, an improved radio frequency (RF) transmission circuit module with low power consumption and helix antenna is designed to improve the performance of video transmission and to extend the working time of the capsule. Simulation and analysis of the circuits and antenna with HFSS12 and ADS2011 software are highlighted. Video capsule endoscope prototypes are made and evaluated to verify the feasibility of the proposed design. In vitro tests and animal experiments show that the results of the antenna tests basically meet the simulation, and the power consumption of RF circuit is 15.9 inV. The video capsule endoscope works well with the receiver with multiple receiving antennas, and the working time is more than 9 h. It can realize the wireless transmission of the video data, and images received are clear and stable in comparison with the previous designs.

关 键 词:video capsule endoscopy radio frequency(RF) transmission circuit helix antenna animal experiment 

分 类 号:TH776.1[机械工程—仪器科学与技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象