检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:廖志伟[1] 岳苓 文福拴[3,4] 朱炳铨[5] 徐立中[5]
机构地区:[1]华南理工大学电力学院,广州市510640 [2]国网山东省枣庄供电公司,山东省枣庄市277100 [3]浙江大学电气工程学院,杭州市310027 [4]文莱科技大学电机与电子工程系 [5]国网浙江省电力公司,杭州市310007
出 处:《电力建设》2016年第2期34-41,共8页Electric Power Construction
基 金:国家高技术研究发展计划项目(863计划)(2015AA050202);高等学校博士学科点专项科研基金资助项目(20120101110112);国网浙江省电力公司科研项目(5211ZD13000R);国家电网公司总部科技项目(52110115009Q)~~
摘 要:对于多重或复杂故障以及存在警报信息丢失或畸变等复杂情况,如何准确诊断所发生的故障和评价保护装置的动作性能仍是值得研究的问题。在此背景下,提出一种基于规则网利用故障录波信息进行高压输电线路故障诊断和评价保护与断路器动作性能的新方法。首先,对故障录波信息进行预处理,利用小波变换技术从电气模拟量信息中提取线路故障特征量,得到电流突变事件和保护动作事件序列。在此基础上,建立计及警报信息时序特性的高压线路故障诊断规则网络模型,并确定故障假说集与期望的保护和断路器状态,并利用它们之间存在的因果与时序关系确定故障原因以及对保护和断路器动作性能进行评价;之后,对故障录波做进一步分析以判别故障类型、故障性质和故障位置;最后,用实际电力系统故障案例对所提出的方法进行说明。For the situations of complicated and multiple faults with missing and/or false alarms, it is still a challenging task to develop an accurate approach for fault diagnosis of high-voltage ( HV ) lines and operating behavior evaluation of protective devices. Given this background, this paper presents a rule-network based approach for this purpose by employing fault recorder data. Firstly, the fault recorder data are pre-processed by using the well-developed wavelet transform to extract the fault characteristics of HV lines from analogue electrical information, and the events of sudden current change and protection action are obtained. On this basis, we construct a rule-network based model for fault diagnosis of HV lines with considering the temporal characteristics of alarm messages, determine the sets of fault hypotheses as well as the expected states of protective relays and circuit breaker, and determine the fault cause and evaluate the performance of protection and circuit breaker with using the causal and temporal relationships between them. In addition, we further analyze the fault recorder to determine the type, characteristics and location of fault. Finally, we adopt actual power system fault cases to demonstrate the proposed method.
关 键 词:高压线路 故障诊断 故障录波信息 规则网络 小波理论
分 类 号:TM755[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7