血浆L-瓜氨酸和L-精氨酸浓度分析方法建立及应用  

Establishment and Clinical Application of the Analytical Method for Plasma L-citrulline and L-arginine Concentration

在线阅读下载全文

作  者:魏玮[1] 茅惠明[2] 陈炳官[2] 熊伍军[3] 徐增光[2] 

机构地区:[1]上海市浦南医院肿瘤科,上海200125 [2]同济大学附属东方医院中心实验室,上海200120 [3]同济大学附属东方医院消化内科,上海200120

出  处:《现代检验医学杂志》2016年第1期28-32,37,共6页Journal of Modern Laboratory Medicine

基  金:上海市浦东新区卫生系统领先人才培养计划项目(PWRL2014-01);上海市浦东新区卫生系统学科带头人培养项目(PWRd2014-03).

摘  要:目的建立反相高效液相色谱(RP—HPLC)-紫外检测法同时测定血浆卜瓜氨酸和L,精氨酸浓度的方法并应用于临床。方法采用三氯乙酸结合加热法除血浆蛋白,用异硫氰酸苯酯(PITC)进行柱前衍生化反应,梯度洗脱,柱温46℃,波长254nm,进样20μl,流速1.0ml/min;通过分析21例消化道晚期恶性肿瘤病人、21例非恶性肿瘤病人和39例健康人的空腹血浆L-瓜氨酸和L-精氨酸浓度,验证方法的可行性。结果两种氨基酸的峰面积和浓度之间呈线性关系,线性范围从0~1000μmol/L,两者r=0.99995。L-瓜氨酸和L-精氨酸的定量下限分别为0.240μmol/L和0.448μmol/L。日内和日间变异系数(CVS)分别小于3.4%和7.2%,平均回收率在95.2%~104.1%。血浆L-瓜氨酸/L-精氨酸的比值均值,消化系统肿瘤病人组高于年龄性别相匹配的健康对照组,差异有统计学意义(t检验,P=0.009);两种氨基酸比值诊断消化系统恶性肿瘤的敏感度和特异度分别为81%和71.4%。结论这一新方法可用于临床测定血浆L-瓜氨酸/和L-精氨酸浓度;与浓度相比,血浆两种氨基酸浓度比值也许是评估消化系统恶性肿瘤更加敏感的指标。Objective To establish a method for simultaneously measuring L-citrulline and L-arginine concentration in plasma using reversed-phase high performance liquid chromatography (RP-HPLC) with ultraviolet detection,and the novel method is applied to the patients with digestive system tumor. Methods Plasma samples were deproteinized by trichloroacetic acid with heating method. Phenylisothiocyanate (PITC) was used as derivatization reagent and a gradient elution was adopted. The feasibility verification of method was carried out by detecting plasma L-citrulline and L-arginine acid concentration in 21 cases of advanced digestive tract malignant tumor patients, 21 cases of non malignant tumor patients and 39 eases of healthy people. Results The linearity for L-citrulline and L-arginine ranged from 0 to at least 1 000 tzmol/L, r=0. 999 95 for both. The lower limits of quantification for L-eitrulline and L-arginine were 0. 240μmol/L and 0. 448 μmol/L respectively. The intraday and interday coefficients of variation (CVs) were less than 3.4% and 7.2% ,respectively. The average recovery rate was from 95.2 % to 104.1%. The ratio of plasma L-citrulline/L-arginine in patients with digestive cancar was significantly higher than that in the healthy control group, t-test, P= 0. 009. The sensitivity and specificity of plasma L-citrulline/L-arginine ratio in the malignant tumor of digestive system were 81% and 71.4% respectively. Conclusion This method can provide a reliable and efficient method for the clinical determination of the L-citrulline and L-arginine concentration in plasma. The ratio of plasma citrulline/arginine increased obviously in patients with digestive cancer, suggesting that this ratio is a more sensitive index than single concentration of L-citrulline or L-arginine when evaluating patients with digestive tumor.

关 键 词:血浆 L-瓜氨酸 L-精氨酸 反相高效液相色谱 异硫氰酸苯酯 三氯乙酸 

分 类 号:R446.112[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象