摘  要:为验证超滤膜物理破损压力衰减监测的有效性,对破损后膜出水水质的变化和膜内压力的衰减情况进行系统考察.借助医用探针在超滤膜上制造破损点(单个扎孔破损率A=5.46×10-6),发现随着破损率由0增加到5A,超滤膜出水的UV254和DOC仅分别增加24%和26%;出水浊度由0.100 NTU增加到0.290 NTU,但绝对值依然很低,难以反映超滤膜破损的程度.超滤膜急性物理破损时,膜内压力则呈现出急剧下降的趋势,即便破损率仅为1A时,55 k Pa的压力仅66 s就降至零点.因此,以压力衰减监测作为超滤膜物理破损的一种快速、高效、灵敏的评价方法是行之有效的.接触实验表明,粉末炭与超滤膜的短期接触(45 d)不会造成超滤膜的慢性物理破损,不会影响出水水质.To verify the effectiveness of ultrafiltration (UF) membrane, the changes of the UF membrane were systematically inv pressure declination monitoring for assessing physical damage of of water qualities in UF permeate and the pressure declination behavior estigated . Medical probe was used to induce the breakage points on UF membrane (the damage rate of single breakage point: A = 5.46 × 10^-6). It was found that as damage percentage increased from 0 to 5A, the DOC and UV254 in permeate only increased by 24% and 26%, respectively; although the permeate turbidity increased form 0.100 NTU to 0.290 NTU, the absolute value is still too low to reflect the degree of membrane damage properly. On the other hand, a sharp decreasing trend of the pressure inside the membrane fibers was observed for the 55 kPa was demonstrated to decrease damaged UF membrane even at the damage percentage of A, the pressure of to zero in only 66 s. Therefore, monitoring the pressure declination behavior can be considered as a fast, efficient and sensitive method for evaluating the damages on UF membrane. Furthermore, exposure tests showed that the contact of UF membrane short-term time (45 d) would not cause physical damage on the UF permeate would be adversely affected by the short-term PAC contact. with powdered activated carbon (PAC) in a membrane, and the water quality of the UF

关 键 词:超滤膜 物理破损 出水水质 压力衰减 粉末活性炭 

分 类 号:TU991.2[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象