AAS法测定纯铼中痕量元素K试验研究  被引量:1

Test and Determination of Trace Potassium in Pure Rhenium by AAS

在线阅读下载全文

作  者:任慧[1,2] 刘广华[1,2] 李蓓[1,2] 

机构地区:[1]中航工业北京航空材料研究院,北京100095 [2]航空材料检测与评价北京市重点实验室,北京100095

出  处:《失效分析与预防》2015年第6期389-392,共4页Failure Analysis and Prevention

摘  要:用AAS法测定纯铼中的痕量元素K。通过优化原子吸收测量条件,研究了硝酸用量以及基体铼对测定K含量的影响,建立了AAS法测定纯铼中痕量元素K的分析方法。结果表明,AAS法测量K的相对标准偏差不大于9.04%,测定范围为0.000 1%~0.001%,方法检出限为0.003 5μg/m L。本检测方法不仅准确可靠,而且简便快速。A method for the determination of trace K in pure rhenium by AAS has been developed. The measuring conditions of AAS have been optimized. The influences of the amount of HNO3 and rhenium on the determination of K in pure rhenium have been investigated. The relative standard deviations of the results obtained by AAS method are lower than 9.04%, the appropriate concentration range is 0.000 1% -0. 001% and the detection limit is 0. 0035 μg·m L-1 The method is not only accurate and reliable but also simple and rapid.

关 键 词:AAS法 纯铼  痕量元素 标准偏差 

分 类 号:O657.31[理学—分析化学]

 