共孔径消热差红外双波段光学系统  被引量:15

Infrared dual band athermal optical system with common aperture

在线阅读下载全文

作  者:白瑜[1,2,3] 廖志远[1] 廖胜[1] 任栖峰[1] 陈为[1] 林妩媚[1] 邢廷文[1] 蒋亚东[2] 

机构地区:[1]中国科学院光电技术研究所,四川成都610209 [2]电子科技大学光电信息学院,四川成都610054 [3]中国科学院大学,北京100049

出  处:《光学精密工程》2016年第2期268-277,共10页Optics and Precision Engineering

基  金:国家自然科学基金资助项目(No.10874181);中国科学院青年创新促进会资助项目

摘  要:设计了适用于制冷型320×256中波红外凝视焦平面阵列探测器和320×256长波红外凝视焦平面阵列探测器的共孔径消热差折反射式红外双波段光学系统。该系统在中波3.7~4.8μm,长波7.7~11.7μm,环境温度10~40℃下工作,其焦距为292mm,视场角为1.56°×1.875°,F/#为1.93,满足100%冷光阑效率。设计的系统共用主镜、次镜和准直镜组,利用分光镜实现中波红外、长波红外光谱分光,后接各自的校正镜组校正剩余像差。给出了设计原理、设计过程和工程设计时需考虑的一些因素,通过选择合适的光学材料、机械材料和分配光焦度,实现了两路系统在10~40℃环境温度下具有良好的成像性能。该系统成像质量良好、可加工性好、装配难度小、工程可实施性强。A set of common aperture athermal catadioptric optical system with infrared dual bands is presented for 320 × 256 MWIR and LWIR staring focal plane array detectors. The system works at the wavelength of 3.7-4.8μm, 7.7-11.7 μm,and the environment temperature of 10-40 ℃. Its working parameters are the effective focal length of 292 mm,field of view of 1.56°× 1. 875°,F/# of 1.93 and the cold shield efficiency of 100 %. The LWIR system shares the primary mirror, secondary mirror and collimating lens with the MWIR system. The beam splitting of the MWIR and LWIR is achieved by a spectroscope and their aberrations are eliminated by correcting lenses respectively. The design principle, design process and some considering factors in engineering design moment are presented. By choosing appropriate optical materials, mechanical materials and assigning the optical power, the common aperture athermal catadioptric optical system obtains good image quality during 10 ℃ to 40 ℃. It shows good imaging quality, good machining ability, easy to be assemble, and suitable for engineering applications.

关 键 词:光学设计 红外光学系统 双波段成像系统 共孔径结构 

分 类 号:TN216[电子电信—物理电子学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象