A near-infrared methane detection system using a 1.654 μm wavelength-modulated diode laser  被引量:1

A near-infrared methane detection system using a 1.654 μm wavelength-modulated diode laser

在线阅读下载全文

作  者:付洋 刘慧芳 隋越 李彬 叶玮琳 郑传涛 王一丁 

机构地区:[1]State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University [2]College of Engineering, Shantou University

出  处:《Optoelectronics Letters》2016年第2期140-143,共4页光电子快报(英文版)

基  金:supported by the National Key Technology R&D Program of China(Nos.2013BAK06B04 and 2014BAD08B03);the National Natural Science Foundation of China(Nos.61307124 and 11404129);the Science and Technology Department of Jilin Province of China(Nos.20120707 and 20140307014SF);the Changchun Municipal Science and Technology Bureau(Nos.11GH01 and 14KG022);the State Key Laboratory on Integrated Optoelectronics;Jilin University(No.IOSKL2012ZZ12)

摘  要:By adopting a distributed feedback laser(DFBL) centered at 1.654 μm, a near-infrared(NIR) methane(CH4) detection system based on tunable diode laser absorption spectroscopy(TDLAS) is experimentally demonstrated. A laser temperature control as well as wavelength modulation module is developed to control the laser's operation temperature. The laser's temperature fluctuation can be limited within the range of-0.02—0.02 °C, and the laser's emitting wavelength varies linearly with the temperature and injection current. An open reflective gas sensing probe is realized to double the absorption optical path length from 0.2 m to 0.4 m. Within the detection range of 0—0.01, gas detection experiments were conducted to derive the relation between harmonic amplitude and gas concentration. Based on the Allan deviation at an integral time of 1 s, the limit of detection(Lo D) is decided to be 2.952×10^(-5) with a path length of 0.4 m, indicating a minimum detectable column density of ~1.2×10^(-5) m. Compared with our previously reported NIR CH_4 detection system, this system exhibits some improvement in both optical and electrical structures, including the analogue temperature controller with less software consumption, simple and reliable open reflective sensing probe.

关 键 词:reflective deviation methane modulated Allan tunable analogue fluctuation decided length 

分 类 号:TP274[自动化与计算机技术—检测技术与自动化装置] TN248[自动化与计算机技术—控制科学与工程]

 