基于风扇强制对流的茯茶烘房数值优化研究  被引量:2

The Study on Numerical Optimization of Fu Brick Tea Drying Room Based on Fan Forced Convectio

在线阅读下载全文

作  者:刘慧[1] 涂福炳[1] 谢韬[1] 刘雄文[1] 匡敬柱 

机构地区:[1]中南大学能源科学与工程学院,湖南长沙410083

出  处:《工业加热》2016年第1期39-41,共3页Industrial Heating

摘  要:以某茯砖茶企业烘房为研究对象,利用FLUENT软件对不同风扇优化方案下的茯茶发花过程中烘房内空气的速度场和温度场进行了稳态的数值模拟。研究结果表明:在不改变现有供热方式的情况下,采用双风扇强制对流能够显著改善烘房内的空气对流状况,使烘房内空气的温度均匀性得到明显提高;烘房内空气的最高温度差由原来的5℃改善为2℃。Based on a typical Fu brick tea drying room of a company, using FLUENT software and numerical simulation method, establish Fu tea drying room "blossom" mathematical model, analysis features of velocity field and temperature field distribution in a drying room. The results show that under the condition of without changing the existing heating way, use the double fan forced convection can significantly improve the chamber air convection condition, makes the air inside the chamber temperature uniformity is improved obviously; the highest temperature difference of the air in the chamber improve from 5 ℃ to 2 ℃.

关 键 词:茯茶烘房 强制对流 数值模拟 优化 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 