检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王静鸽[1] 付洪波[1] 倪志波[1] 贺文干 陈兴龙[1,2] 董凤忠[1,3]
机构地区:[1]中国科学院安徽光学精密机械研究所安徽省光子器件与材料重点实验室,安徽合肥230031 [2]合肥工业大学仪器科学与光电工程学院,安徽合肥230009 [3]中国科学技术大学环境科学与光电技术学院,安徽合肥230026
出 处:《光谱学与光谱分析》2016年第3期817-822,共6页Spectroscopy and Spectral Analysis
基 金:国家自然科学基金项目(11075184);中国科学院合肥物质科学研究院知识创新工程领域前沿项目(Y03RC21124)资助
摘 要:为了研究再加热双脉冲激光诱导击穿光谱(LIBS)对信号的增强机制,分别采用单脉冲LIBS和再加热双脉冲LIBS两种方式烧蚀合金钢样品产生等离子体,利用高分辨率的中阶梯光栅光谱仪采集等离子体发射光谱信号,同时用快速成像ICCD相机观测等离子体形态的变化,研究了两种烧蚀方式下等离子体的时空演变特性。通过比较两种烧蚀方式下等离子体产生初期光谱信号和图像的时间演变规律,发现再加热双脉冲LIBS提高了等离子体温度,且当信号采集延时等于再加热双脉冲的脉冲间隔时,等离子体温度的衰减速率发生变化;再加热双脉冲LIBS使等离子体图像强度增加,等离子体的中心区域高度和宽度分别增大了23.5%和15.1%。空间分布的研究结果表明,与单脉冲LIBS相比,当到样品表面的距离大于0.6mm时,等离子体中的FeⅡ和NⅠ谱线强度有较明显的增强,而FeⅠ谱线在空间不同位置处的增强程度都较小,局部区域有减小的现象;再加热双脉冲LIBS使等离子体温度增加了约2 000K,等离子体中产生了一个较大的高温区域。综合时空演变的实验结果说明再加热双脉冲对光谱信号增强的机制主要是由于第二束激光对第一束激光烧蚀样品产生的等离子体再次激发,使等离子体温度增加,进而引起等离子体辐射强度增加。In order to investigate the emission enhancement mechanisms of reheating Double Pulse Laser-Induced Breakdown Spectroscopy(DP-LIBS),single pulse LIBS(SP-LIBS)and reheating DP-LIBS were carried out on an alloy steel sample respectively.The plasma emission was collected by an Echelle spectrometer with high resolution,while the plasma structure was monitored via fast-photography.The temporal and spatial evolutio ns of the plasma generated by SP-LIBS and reheating DP-LIBS were being studied.It is found that the plasma temperature in reheating DP-LIBS was higher than that of SP-LIBS,and there was a turning point for the decay rate of plasma temperature in reheating DP-LIBS when the delay time was equal to the interpulse time of DP-LIBS.Moreover,the inte nsity of the plasma image was increased by reheating DP-LIBS,and the height and width of the central region of the plasma were increased about 23.5%and 15.1%respectively.The results of spatial distribution showed that the inte nsity of FeⅡ and N I lines in the plasma were obviously enhanced by reheating DP-LIBS when the distance from the sample surface was larger than 0.6mm.While the inte nsity enhancement for FeⅠlines were little,even in some positio ns the inte nsity of Fe Ⅰ lines decreased.The plasma temperature of double-pulse configuration was about 2 000 Khigher than that of SP-LIBS,and a larger hot region in the plasma was generated.It is evidenced that the emission enhancement mechanisms in reheating DP-LIBS is that the second laser pulse re-excited the plasma induced by the first laser pulse,and the higher plasma temperature resulted from the re-exciting process.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30