抽水蓄能机组单导叶调速器开度不同步故障的模式影响分析  

Asynchronous Opening Fault Diagnosis in Independent Wicket Gates Governor System Based on Failure Mode and Effects Analysis

在线阅读下载全文

作  者:陈鑫[1] 王彬[1] 申思[2] 杨旼才 

机构地区:[1]山东泰山抽水蓄能电站有限责任公司,山东泰安271000 [2]华北电力大学控制与计算机工程学院,北京102206

出  处:《应用能源技术》2016年第2期5-8,共4页Applied Energy Technology

基  金:国家自然科学基金(61203107);国网新源公司科技项目(SGXY-2015FJ03-487)

摘  要:单导叶调速器具有调节灵敏、调节精度高等优点,被推广应用于大型抽水蓄能机组。文中针对单导叶调速器易发生的导叶开度不同步故障,利用模式影响分析方法对典型故障特征、原因及影响、检测方法、解决措施等问题进行了研究,给出了两类典型故障的模式影响分析表,对于提高该类机组的运行可靠性具有一定的指导意义。Independent wicket gates governor, who has sensitive regulatory function and can lead to a consequence with high precision, was widely used in large pumped storage power station. In this paper, the failure mode and effects analysis method is used to analyze the asynchronous opening faults. Typical fault characteristics, fault causes and effects, fault monitoring techniques, and trouble solving measures are studied systematically. Failure mode and effects analysis tables are proposed to describe two typical faults. The result obtained is of importance in improving the operation reliability of the large pumped storage power station.

关 键 词:单导叶控制 导叶不同步故障 故障模式影响分析 

分 类 号:TK733.8[交通运输工程—轮机工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 