检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张莉[1,2] 郑海洋[1] 王颖萍[1] 丁蕾[1] 方黎[1]
机构地区:[1]中国科学院安徽光学精密机械研究所环境光谱学研究室,合肥230031 [2]中国科学院大学,北京100049
出 处:《物理学报》2016年第5期134-143,共10页Acta Physica Sinica
摘 要:为了发展远距离探测未知或危险物质的方法,设计并建立了近同轴可见光远距离拉曼光谱探测实验装置,对硝酸盐固体样品进行了距离为2-10 m的拉曼光谱测量,初步研究了拉曼信号强度与激发光功率、探测距离、样品浓度及样品表面方向之间的关系.实验观察到三种硝酸盐在1050 cm^(-1)附近的拉曼谱线,其微小的差异可作为识别特征.硝酸铵的特征拉曼谱线强度正比于激发光功率,近似平方关系;与探测距离之间趋向于二次反比关系;与样品浓度接近指数关系;与样品表面朝向有近似余弦函数的关系.For developing a method to detect unknown or hazardous materials beyond safe distances,an experimental standoff detection system with using Raman scattering is established in laboratory.It consists of a pulsed laser with a wavelength of 532 nm as an excitation source,an optical assembly for light collecting and focusing with a 25 mm entrance aperture,a grating monochromator for dispersing scattering light,and a photomultiplier connected to an oscillograph for signal monitoring.The angle between the direction of incident laser beam and that of the scattering light collecting assembly is less than 2°.Raman signal intensities of ammonium nitrate,potassium nitrate and sodium nitrate in solid samples in a distance range from 2 m to 10 m are measured.The results are supposed to be comparable to those obtained in a distance range from 20 m to 100 m if a telescope of 250 mm diameter is used instead to collect Raman scattering light as in a usual standoff detection system.Some characteristics of Raman spectra are investigated,such as the spectrum features,the relationships between the amplitude of the highest Raman peak of ammonium nitrate and the intensity of the excitation light,the detection distance,the concentration of the sample and the normal direction of the sample surface.The Raman spectra of ammonium nitrate,potassium nitrate and sodium nitrate look similar:each of them has a highest peak in the vicinity of 1050 cm^-1,small difference can be observed,and it can serve as a "signature" for discriminating between them.The experimental results demonstrate that the intensity of the characteristic Raman spectrum of ammonium nitrate is proportional to the excitation power,with approximate quadratic relationship,and tends to be inversely proportional to the square of the detection distance except that the detection distance is too short to ignore the influence of the focal length of light collecting optics on image size.In addition,the intensity of the characteristic Raman spectrum of ammonium nitrate decays appr
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.139.83.202