氢化物原子荧光光谱法测定水消毒剂次氯酸钠中的砷  被引量:3

Determination of Arsenic in Water Disinfectant Sodium Hypochlorite with Hydride Atomic Fluorescence Spectrometry

在线阅读下载全文

作  者:许小燕[1] 董晓晨[1] 俞蕴芳 张泾凯[1] 刘玉红[1] 岳攀[2] 何敏[1] 蒋颖[1] 

机构地区:[1]苏州工业园区清源华衍水务有限公司,江苏苏州215021 [2]苏州工业园区疾病防治中心,江苏苏州215021

出  处:《中国给水排水》2016年第6期88-90,共3页China Water & Wastewater

摘  要:用氢化物原子荧光光谱法测定水消毒剂次氯酸钠中的砷。该方法测定浓度范围可达0.03~100μg/L,拟合标准曲线的相关系数为0.9996,检出限为0.003ug/g,加标回收率在96.0%~104.6%之间,测定结果的RSD在0.26%~2.12%之间,满足水消毒剂检测要求。The hydride atomic fluorescence spectrometry was used to determine arsenic in sodium hypochlorite used as water disinfectant. The results indicated that the method allowed the measurement of arsenic over the range of 0.03 to 100μg/L with a correlation coefficient of 0.999 6 and a detection limit of 0. 003μg/g. The recoveries of the method ranged from 96.0% to 104.6% , and the relative standard deviation ranged from 0.26% to 2.12%. All these could meet the requirements for water disinfectant detection.

关 键 词:氢化物原子荧光光谱法 次氯酸钠  

分 类 号:TU991.2[建筑科学—市政工程]

 