SJ-10卫星导线特性箱实验装置研制  

Experimental facility for wire insulation combustion in SJ-10

在线阅读下载全文

作  者:孔文俊[1] 王宝瑞[1] 夏伟[1,2] 

机构地区:[1]中国科学院工程热物理研究所中国科学院轻型动力重点实验室,北京100190 [2]中国科学院大学,北京100039

出  处:《物理》2016年第4期219-224,共6页Physics

基  金:中国科学院空间科学战略性先导科技专项(批准号:XDA04020202-08;XDA04020408)

摘  要:为了研究微重力条件下导线绝缘层着火先期征兆和着火早期烟的析出和烟气流动规律,研制了SJ-10卫星导线特性箱有效载荷实验装置。该装置可实现对导线的恒流过载加热,并采用先进的测试技术,获得导线着火先期征兆和烟气浓度分布。地面验证实验表明,该装置安全可靠,同时能充分利用空间实验能力,保障科学目标的实现。In order to study pre- ignition characteristics,smoke release and distribution characteristics of wire insulation under microgravity,hardware of the wire insulation was conducted. The facility can achieve the wire insulation preheating by overload. Advanced test technology is adopted to obtain the early signs of ignition and the distribution of smoke concentration in the flue gas. The experimental results valid that the hardware is safe and reliable,and it can make full use of the space experiment ability to ensure the realization of the scientific objectives.

关 键 词:导线绝缘层 电流过载 着火征兆 碳烟生成 实践十号卫星 

分 类 号:V416.8[航空宇航科学与技术—航空宇航推进理论与工程]

 