示踪气体技术在核电厂主控室内漏测量的应用  被引量:5

Application of Tracer Gas Test Technique Used in In-Leakage Test of Main Control Room in Nuclear Power Plant

在线阅读下载全文

作  者:黄海涛[1] 沈杰[1] 杨炯[1] 

机构地区:[1]国核电站运行服务技术有限公司,上海200233

出  处:《能源与节能》2016年第4期87-89,共3页Energy and Energy Conservation

摘  要:介绍了广泛应用于通风系统测量的示踪气体技术,重点介绍其中的恒定流量法的基本原理和实际应用。通过分析恒定流量法在矿井漏风量测量上的应用,并对比矿井漏风量测量与核电厂主控室内漏测量的异同点,探讨了将矿井漏风量测量技术应用到主控室内漏测量的可行性,设计出可行的主控室内漏测量方案。The paper described tracer gas technique which was widely used in air ventilation system, and focused on the basic principle and practical application of constant flow technique. By analyzing the application of constant flow technique in leakage air volume test in mining industry, and making comparation on similarities and differences of mine shaft leakage test and main control room in-leakage test, this paper discussed the applied feasibility of mine leakage air volume test technique in in-leakage test of main control room test, and gave a feasible plan of in-leakage test in main control room.

关 键 词:示踪气体 恒定流量法 主控室 内漏量 

分 类 号:TD723[矿业工程—矿井通风与安全]

 