检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]电力电子国家专业实验室(浙江大学),浙江省杭州市310027
出 处:《中国电机工程学报》2016年第7期1900-1907,共8页Proceedings of the CSEE
基 金:国家重点基础研究发展计划(973)青年科学家专题(2014CB247400);国家自然科学基金项目(51490682)~~
摘 要:为了提高全桥子模块的运行可靠性,该文研究全桥子模块的损耗分布,并提出一种损耗分布优化的控制方法。首先,根据全桥子模块的输出特性及其器件的损耗特征推导出子模块损耗分布的解析表达式,由此揭示出功率输出对损耗的影响。其次,根据损耗分布表达式,分析全桥子模块冗余开关状态对损耗分布的影响,确定可实现损耗均衡的冗余开关状态投切原则。最后,为了实现上述投切原则,引入轮换及结温反馈两种调制方法对开关状态投切进行控制,并通过仿真验证损耗分布分析的正确性及所提方法的有效性。In order to promote the reliability of the full bridge submodule, its loss distribution as well as its loss balance strategy was investigated. At first, through a theoretical analysis method, the loss distribution in full-bridge sub-module was derived and the fundamental factor that causes loss imbalance was disclosed. And then, the effects of redundant switching states on loss distribution in full bridge submodule were investigated. As a result, the optimal principle about how to use redundant switching state to relive imbalance loss distribution was proposed. Finally, in order to achieve the optimal switching principle, the loss balance strategy based on online loss calculation was addressed. Meanwhile, above analysis were also verified by PLECS simulation results.