检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中原工学院,郑州450000
出 处:《建筑节能》2016年第4期19-21,共3页BUILDING ENERGY EFFICIENCY
基 金:河南科技攻关项目(122102210557)
摘 要:在夏热冬冷地区,传统式单独运行的地埋管式地源热泵在夏季对土壤的蓄热量大于在冬季的取热量,常年运行会造成土壤热失衡及热泵机组运行效率降低的情况。冷却塔式复合地源热泵系统可利用冷却塔辅助散热,通过分析其组成结构、工作原理和分类特点,确认控制温差和调节冷却塔运行时间等方法可改善热泵运行的工作效率,保持地埋管附近土壤的热平衡,同时在降低热泵机组初投资、运行维护费用,以及减少占地面积等方面优势明显。The annual operation of the traditional ground source heat pump system where the soil heat storage in summer is larger than the heat taking in winter will cause the soil heat imbalance and efficiency reduction. By using the composite ground-coupled heat pump with a cooling tower, and analyzing the pump's structure, operational principle and classification, control strategies including controlling the range of temperature and cooling tower working mode will improve the work efficiency and soil thermal imbalance. The composite ground-coupled heat pump with a cooling tower can also reduce theinitial investment, operation cost and area of the system.
关 键 词:冷却塔式复合地源热泵系统 工作原理 工作效率 控制方法
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.92.7