磁絮凝-膜过滤组合工艺处理微污染原水的实验研究  被引量:2

Experimental Study on Treatment of Micro Polluted Raw Water by Combined Process of Magnetic Flocculation and Membrane Filtration

在线阅读下载全文

作  者:庞治邦 姚吉伦[2] 刘波[1] 周振[1] 

机构地区:[1]后勤工程学院国防建筑规划与环境工程系 [2]后勤工程学院国家救灾应急装备工程技术研究中心,重庆401331

出  处:《水处理技术》2016年第4期21-24,共4页Technology of Water Treatment

基  金:国家科技支撑计划(2012BAK05B03)

摘  要:采用磁絮凝-陶瓷膜过滤组合工艺对微污染水进行处理,研究不同条件下的出水水质,分析PAC投加量、磁粉投加量以及磁化时间对出水水质的影响。通过正交实验确定其主要影响因素的最佳水平组合:PAC投加量为25 mg/L,磁粉投加量为8 mg/L,磁化时间为6 min。在此条件下对浑浊度、UV和COD的去除率可分别达到92.32%、58.50%和43.40%。Micro polluted water was treated by magnetic flocculation and ceramic membrane filtration process. The quality of effluent was studied. The effects of, magnetic particles dosage and the magnetization time on the quality of the effluent were studied. Through orthogonal experiment to obtain the main influencing factors of the optimal level combination: PAC dosage is 25 rag/L, the magnetic particles dosage is 8 rag/L, and the magnetization time is 6 min. Under these conditions, the removal rates of tnrbidity, UV and COD can reach 92.32%, 58.50% and 43.40% respectively.

关 键 词:磁絮凝 陶瓷膜过滤 出水水质 正交实验 