检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:伍小亭[1,2] 胡斌[1] 郭春梅[1] 孔令霞[1]
机构地区:[1]天津城建大学能源与安全工程学院 [2]天津市建筑设计院
出 处:《建筑热能通风空调》2016年第3期43-46,42,共5页Building Energy & Environment
摘 要:水系统变流量运行可以减少输配能耗,地源热泵地源侧变流量技术还处于研究阶段,与冷却水系统有着相似之处。冷却水变流量运行的节能效果与冷却水泵的能耗比例相关,比例越大节能效果越显著,而地埋管地源热泵的地源侧管路复杂多变且管程较长,地源水在流动过程中所产生总阻力比冷却水的总阻力大,循环水泵的功率也相对较大,研究地源水的变流量技术更有意义。The variable flow of water system operation can reduce the energy consumption of distribution. The technology of variable heat pump ground source water flow rate system is still on research stage which is similar to the cooling water system. The energy saving effect operated by variable cooling water flow rate is related to proportion of energy consumption of cooling water pump, so energy saving effect is more significantly with larger proportion. Ground source side pipeline of ground source heat pump of underground pipe is complicated and tube side is very long, which brings larger total resistance and bigger energy consumption than cooling water system, so the research on technology of variable ground source water flow rate is more significant.
分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]