检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:詹利军[1] 刘刚[1] 甘长德[1] 魏曙光[1]
机构地区:[1]东华大学环境科学与工程学院
出 处:《建筑热能通风空调》2016年第3期56-59,共4页Building Energy & Environment
摘 要:冰蓄冷空调系统控制策略有多种形式,又各有其优缺点。本文将制冷主机运行效率与冰蓄冷空调系统运行策略结合起来,通过计算制冷主机逐时COP值,找到一种更加适合冰蓄冷空调的运行策略,可以大幅节省运行费用和降低运行能耗,实现国家、电商、用户的共利同赢。There are many forms in ice-cool-storage air-conditioning control strategy, and each has its advantages and disadvantages. To find a more suitable for the operation strategy of cool storage air conditioner, through the calculation of chiller hourly COP value, the chiller efficiency and the operation strategy of an ice-storage air conditioning system was put together. It can saving operating costs, reduce energy consumption and achieve the commensalism of country, electricity supplier and users while combining chiller's operating efficiency with ice storage air conditioning system's operating strategy.
关 键 词:冰蓄冷空调 冰片滑落式 制冷机效率 优化控制 经济性