检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李行方[1] 尹江伟[1] 付斌[1] 钟伟燕[1] 吴礼康[1]
机构地区:[1]深圳市宝安区疾病预防控制中心,广东深圳518101
出 处:《中国职业医学》2016年第2期201-204,共4页China Occupational Medicine
摘 要:目的改进工作场所空气中环己烷与甲基环己烷的溶剂解吸-气相色谱测定方法。方法采用活性炭管采集样品,二硫化碳解吸,经DB-1毛细管色谱柱分离,火焰离子化检测器检测,标准曲线法定量。结果本方法环己烷与甲基环己烷的质量浓度分别在1.0~1 402.2与0.8~1 999.4 mg/L范围内呈线性关系,相关系数均为0.999 9;检出限均为0.3 mg/L,定量下限分别为1.0和0.8 mg/L,最低检出浓度均为0.2 mg/m^3,最低定量浓度分别为0.7和0.6 mg/m^3(以采集1.5 L工作场所空气计);平均解吸效率分别为98.5%~99.3%和97.6%~99.0%;批内相对标准偏差(RSD)分别为0.36%~0.59%与0.34%~0.50%,批间RSD分别为0.89%~2.04%与0.87%~2.22%;样品在室温下可保存7 d。结论本方法灵敏度高,精密度好,操作简单,可用于同时测定工作场所空气中环己烷与甲基环己烷。Objective To explore an improved method for determination of cyclohexane and methylcyclohexane in workplace air by solvent desorption-gas chromatography. Methods Cyclohexane and methylcyclohexane in workplace air were collected by activated carbon tubes,desorbed with carbon disulfide,separated by DB-1 capillary chromatography column,detected by flame ionization detector and quantified using the standard calibration curves. Results The linear range of the concentration of cyclohexane and methylcyclohexane were 1. 0-1 402. 2 and 0. 8-1 999. 4 mg / L respectively.Both the correlation coefficients were 0. 999 9. Both the detection limits were 0. 3 mg / L. The limits of quantification were1. 0 and 0. 8 mg / L respectively. Both the minimum detectable concentrations were 0. 2 mg / m^3. The minimum quantitative mass concentrations of cyclohexane and methylcyclohexane were 0. 7 and 0. 6 mg / m^3respectively( sample volume was 1. 5L). The average desorption efficiencies were 98. 5%-99. 3% and 97. 6%-99. 0% respectively. The relative standard deviations( RSD) of within-run precision were 0. 36%-0. 59% and 0. 34%-0. 50% respectively. The RSD of between-run precision were 0. 89%-2. 04% and 0. 87%-2. 22% respectively. The samples could be stored for up to 7 days at room temperature. Conclusion This method has features of simple operation,high sensitivity and good precision,which is suitable for simultaneous determination of cyclohexane and methylcyclohexane in workplace air.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.224.32.173