检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李莉[1] 张国辉[1] 孙爱芹[1] 何卫[1] 魏玲艳[1]
机构地区:[1]中国石化中原油田分公司技术监测中心,河南濮阳457001
出 处:《石油工业技术监督》2016年第4期43-44,60,共3页Technology Supervision in Petroleum Industry
摘 要:除硫剂中游离碱的测定对于产品质量的判定有着重要意义。阐述了GB 19106-2013《次氯酸钠》检验方法中存在的不足及新方法改进的要点,介绍了除硫剂溶液中游离碱含量测定的新方法。通过实验分析与改进,提高了除硫剂溶液中游离碱测试的重复性。改进后的方法准确、快速、实用,且重复性极高,检测结果均符合允差不大于0.04%的标准要求。The determination of the free alkali in sulfur removal agents is of great significance to the determination of product quality.The shortcomings existing in GB 19106-2013 "sodium hypochlorite " test method and the key points to be improved in the method are expounded, and a new determination method of free alkali content in sulfur removal agent solution is introduced, which improves the repeatability of free alkali test in sulfur removal agent solution. The improved method is accurate, rapid and practical, and it is of high repeatability. The error of detection results is less than 0.04%, which meets the requirements in the standard.
分 类 号:TE39[石油与天然气工程—油气田开发工程]