检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]上海理工大学环境与建筑学院,上海200093 [2]上海理工大学艺术设计系,上海200093
出 处:《建筑结构》2016年第10期20-23,共4页Building Structure
摘 要:为研究预制夹芯保温L形剪力墙在低周反复荷载作用下的受力性能、破坏特点和抗震性能,对4个夹芯保温L形剪力墙试件(3个为全预制试件,1个为现浇对比试件)进行拟静力试验,研究各个试件的破坏形态、承载能力、滞回曲线、骨架曲线、刚度退化及耗能能力。试验结果表明:轴压比对预制夹芯保温L形剪力墙抗震性能的影响明显;预制夹芯保温L形剪力墙具有良好的抗震性能,可代替现浇夹芯保温剪力墙用于实际工程中。To study the mechanical behavior,failure feature and seismic behavior of L-shaped precast sandwich insulation shear wall,pseudo-static tests on four L-shaped precast sandwich insulation shear wall specimens( including three wholly precast specimens and one cast-in-situ specimen for comparison) were conducted to study the failure mode,bearing capacity,hysteretic curve,skeleton curve,stiffness degradation and energy dissipation capacity of specimens. The results show that: the influence of the axial compressive ratio on the seismic behavior of the L-shaped precast sandwich insulation shear wall is obvious; L-shaped precast sandwich insulation shear wall has good seismic behavior and it can be a good substitute for in-situ sandwich insulation shear wall used in practical engineering.
正在载入数据...