检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐彬[1] 王松涛[1] 曾二贤[1] 吴海洋[1]
出 处:《电力勘测设计》2016年第2期58-62,共5页Electric Power Survey & Design
摘 要:为正确评价输电线路的安全性,本文以输电线路元件(导地线、绝缘子和金具)作为分析对象,建立了可靠度分析模型,通过分析影响输电线路元件荷载效应的永久荷载、风荷载的计算公式以及分布曲线,得到荷载效应的统计参数;考虑材料性能不定性、几何参数不定性和计算模式不定性,得到抗力统计参数。采用一次二阶矩方法,计算得到输电线路元件在大风工况下的可靠度指标。结果表明,按现行输电线路规范的安全系数设计的输电线路元件,其可靠度水平较高。For the correct evaluation of the safety of the transmission line, taking the transmission line elements (conductor&earth wire, insulator and hardware) as the analysis objects, the reliability analysis model was established, by analyzing the affecting factors of load effect of transmission line elements such as the calculation formula and distribution curve of permanent load and wind load, the statistical parameters of load effect were obtained;Considered the uncertainty of material properties, geometry and computational model, the resistance statistical parameters were obtained. Using a second-order moment method, calculated the reliability index of the transmission line element in maximum wind condition .Results show that the reliability level of the transmission line elements designed by current speciifcation of safety factor was high. The calculation results can provide reference for the establishment of probability limit state design methods of the transmission line.
分 类 号:TM75[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.184