夏季潮湿地区不同THIC空调系统综合COP对比分析  被引量:5

Analysis of the System COP of Different THIC Air Conditioning Systems in Humid Regions in Summer Season

在线阅读下载全文

作  者:杨昌智[1] 罗志文[1] 蒋新波[1] 

机构地区:[1]湖南大学土木工程学院,湖南长沙410082

出  处:《湖南大学学报(自然科学版)》2016年第5期144-150,共7页Journal of Hunan University:Natural Sciences

基  金:湖南省自然科学基金资助项目(12JJ3053)

摘  要:以温湿度独立控制空调系统作为研究对象,建立了不同形式温湿度独立控制空调系统模型.通过一实际工程对各系统的COP进行分析、计算,揭示了不同温湿度独立控制系统自身的性能和地区差异.通过对比发现,在室外空气含湿量相对较小的地区应优先考虑热泵转轮除湿系统,对于室外含湿量相对较大的地区适合选择溶液除湿系统和冷凝除湿系统.Taking temperature and humidity independent control air conditioning system as the research project, different models of the system have been established. Through analysis and calculation of each sys- tem's COP of a practical engineering project, it reveals the differences in performance and regional differ- ences of the independent control system itself. By comparison, the heat pump wheel dehumidification sys- tem should be considered first,where the outdoor air humidity ratio is relatively small. On the other hand, the liquid desiccant dehumidification system and condensate system may be better where the ratio is rela- tively large.

关 键 词:空调 夏季潮湿地区 温湿度独立控制 COP 

分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]

 