检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈建伟[1] 钱洲亥[1] 祝郦伟[1] 沈晓明[1]
机构地区:[1]国网浙江省电力公司电力科学研究院,杭州310014
出 处:《腐蚀与防护》2016年第5期371-374,共4页Corrosion & Protection
基 金:国家电网公司科技资助项目(ZDK/GW001-2012);浙江省电力公司科技项目(5211DS1350JP)
摘 要:采用电化学噪声测试技术对变电站接地网土壤腐蚀状况进行实时在线监测。结果表明:接地网环境发生改变时,对土壤腐蚀特性有较大影响,接地网腐蚀状态变化较大。电化学噪声监测系统对土壤腐蚀环境的变化反应灵敏,能够进行实时准确的监控预警,可用于变电站基建勘察以及运行维护阶段的腐蚀监控。The substation grounding grid corrosion status was in real-time and online monitored using electrochemical noise technology.The results show that the change of grounding grid environment had a great effect on soil corrosion characteristics and led to great changes of the grounding grid corrosion.Electrochemical noise monitoring system is sensitive to the changes of environment and may implement real-time accurate monitoring and warning,and thus it can be used for corrosion monitoring in the stages of substation construction survey and operation.