检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘浩[1] 唐建群[1] 巩建鸣[1] 温永彬[1]
机构地区:[1]南京工业大学机械与动力工程学院,南京211816
出 处:《腐蚀与防护》2016年第5期398-401,共4页Corrosion & Protection
基 金:江苏省普通高校研究生科研创新计划(CXZZ13_0433)
摘 要:利用硫酸-硫酸铜腐蚀试验方法和双环电化学动电位再活化法(DL-EPR),对304不锈钢薄板在预应变和敏化之后的晶间腐蚀敏感性进行了研究。采用金相显微镜对经过硫酸-硫酸铜试验后的试样进行观察,利用电化学测试方法进行试样敏化度(DOS)的测量。结果表明:304不锈钢薄板经过预应变-敏化处理后的晶间腐蚀程度较经单一敏化处理后的更加严重,随着预应变的加大,晶间腐蚀加重,敏化度也提高。The susceptibility to intergranular corrosion for 304 stainless steel that had been pre-strained and sensitized was investigated by the methods of sulfuric acid-copper sulfate test and double-loop(DL)electrochemical potentiokinetic reactivation(EPR).The microstructures of the experimented specimens after sulfuric acid-copper sulfate testing were observed by optical microscope.The degrees of sensitization for the specimens were measured by electrochemical testing.The results showed that 304 stainless steel sheets that had been pre-strained and sensitized suffered from serious intergranular corrosion as compared to the sheets that only experienced sensitization processing.The susceptibility to intergranular corrosion and the degree of sensitization increased with the increase of the prestrain for 304 stainless steel sheet.
关 键 词:304不锈钢薄板 硫酸-硫酸铜试验 动电位再活化法(EPR) 预应变 敏化 晶间腐蚀
分 类 号:TG174[金属学及工艺—金属表面处理]