改良及传统子宫输卵管造影检查对比剂逆流分析  被引量:6

Comparative Analysis of Reflux of Contrast Agents in Improved and Conventional Treatment of Hysterosalpingography

在线阅读下载全文

作  者:陈明江 

机构地区:[1]兴义市人民医院影像科,贵州兴义562400

出  处:《贵阳医学院学报》2016年第5期581-583,共3页Journal of Guiyang Medical College

基  金:贵州省黔西南州科技计划项目(2015-2-08)

摘  要:目的:观察传统子宫输卵管造影(HSG)方法和改良HSG方法在对比剂逆流发生中的差异。方法:2 143例子宫输卵管造影检查患者,71例采用传统HSG,2 072例采用改良HSG,比较两种造影方法发生对比剂逆流的病例数、逆流程度特征。结果:传统HSG发生逆流8例(11.27%),显著逆流7例(9.86%),轻微逆流1例(1.41%);改良HSG发生逆流68例(3.28%),显著逆流18例(0.87%),轻微逆流50例(2.41%);改良HSG逆流发生率低于传统HSG,差异有统计学意义(P<0.05)。结论:改良HSG可明显降低对比剂逆流的发生率。Objective: To observe the difference between conventional hysterosalpingography( HSG)and the improved method of hysterosalpingography in contrast agent reflux. Methods: 2 143 cases of hysterosalpingography were analyzed,71 cases were treated with conventional HSG,2 072 cases with improved HSG. The number of cases and the degree of contrast characteristics of countercurrent reflux of two methods were compared. Results: Conventional HSG occurred refluzx in 8 cases( 11. 27%),significant reflux in 7 cases( 9. 86%),mild reflux in 1 case( 1. 41%),improved HSG occurred reflux in 68 cases( 3. 28%),significant reflux in 18 cases( 0. 87%),mild reflux in 50 cases( 2. 41%). Conclusion: The improved HSG can significantly reduce the incidence rate of contrast agent reflux,and the significant reflux incidence rate is low.

关 键 词:子宫输卵管造影术 造影剂 逆流 改良 

分 类 号:R816.91[医药卫生—放射医学]

 