钢框架加强型梁柱节点子结构的抗冲击性能试验研究  被引量:7

Experimental study on impact behavior of strengthened beam-column connections of steel frames

在线阅读下载全文

作  者:霍静思[1,2] 王海涛[1] 王宁[1] 张素青[1] 

机构地区:[1]湖南大学教育部建筑安全与节能重点实验室,湖南长沙410082 [2]华侨大学土木工程学院,福建厦门361021

出  处:《建筑结构学报》2016年第6期131-140,共10页Journal of Building Structures

基  金:国家自然科学基金项目(51078139);教育部新世纪优秀人才计划项目(NCET-11-0123)

摘  要:设计了采用FEMA 350过焊孔构造的1个普通栓焊连接和2个加强型(盖板和翼缘加强型)栓焊连接的钢框架梁柱节点子结构试件,对试件进行落锤冲击来模拟结构的动态倒塌过程,考察栓焊节点加强方式对钢框架梁柱节点抗冲击性能的影响。通过试验获得节点试件的破坏形态及其冲击作用和位移时程曲线,分析试件冲击作用和位移时程响应规律以及子结构动态转角和耗能变化趋势。试验结果表明:节点试件的主要破坏形态是显著整体弯曲变形和钢梁上翼缘塑性铰截面附近处受压屈曲,采用FEMA 350标准过焊孔构造的节点试件具有良好的抗冲击转动能力,3个试件的极限转角均达到了FEMA 350规范抗震设计的转角限值(普通栓焊节点为θ=0.054 rad、加强型节点为θ=0.070 rad)要求;改进后的盖板加强型和翼缘加强型节点试件的抗冲击能力均得到显著提高,优于普通栓焊节点。通过分析冲击过程中试件截面内力发展规律可知,由于节点过早破坏,限制了悬链线效应的形成,所有试件最终还处于塑性受弯向悬链线发展阶段。One ordinary bolt-welded beam-column connection specimen and two reinforced ( cover plate reinforced and flange plate reinforced) bolt-welded beam-column connection specimens of steel frame with FEMA 350 weld access hole were designed based on the Chinese seismic code and relevant references. The impact tests using drop-hammer were carried out to simulate the dynamic behavior of structural progressive collapse. The influence of reinforcing methods for the beam-column connection on the impact resistance of steel frame substructure was investigated. The failure modes and time histories of impact load and deformation were obtained, and the dynamic responses of the impact load and deformation time histories were analyzed as well as the dynamic rotation and energy dissipation of the substructures. Test results show that bolt-welded beam-column connection specimens fail mainly due to the remarkable global bending deformation and local buckling of steel beam flange near the plastic hinge section. The specimens with FEMA 350 weld access hole have good rotation capacity to resist impact loading, while its ultimate rotation is not less than the FEMA 350 design limit (ordinary bolt-welded connection: 0 = 0. 054 rad, improved bolt-welded connection: 0 = 0. 070 rad). The impact resistance of strengthened connection specimens is improved significantly, which is better than that of ordinary bolt-welded connection. The internal force development of specimens during the impact loading was analyzed. It is demonstrated that the premature failure of the bolt-welded beam-column connection degrades the formation of catenary action. The ultimate state of specimens were still in the development stage from plastic bending status to the formation of eatenary action.

关 键 词:钢框架梁柱节点 加强型 冲击试验 悬链线效应 抗倒塌能力 

分 类 号:TU973.13[建筑科学—结构工程] TU317.1

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象