时域脉冲平衡零拍探测器的高精度自动平衡  被引量:4

Highprecision auto-balance of the time-domain pulsed homodyne detector

在线阅读下载全文

作  者:刘建强[1,2] 王旭阳[1,2] 白增亮[1,2] 李永民[1,2] 

机构地区:[1]山西大学光电研究所,量子光学与光量子器件国家重点实验室,太原030006 [2]山西大学,极端光学协同创新中心,太原030006

出  处:《物理学报》2016年第10期24-30,共7页Acta Physica Sinica

基  金:国家自然科学基金(批准号:61378010,11504219);山西省自然科学基金(批准号:2014011007-1);山西省高等学校创新人才支持计划资助的课题

摘  要:时域脉冲平衡零拍探测器能够直接对光场量子态的正交分量进行测量,是连续变量量子密钥分发系统的核心测量器件,其测量精度与密钥分发系统的额外噪声及安全密钥速率密切相关.本文理论分析了探测器双臂不平衡对测量精度的影响,并实验设计、研制了双臂可精确自动平衡的时域脉冲平衡零拍探测器.通过高精度控制探测器一臂的光纤圆环曲率半径,实现了光纤内部光场强度的精密衰减,进而获得了探测器的精确自动平衡.实验测试结果表明时域平衡零拍探测器双臂具有10^(-5)以上的平衡精度,能够长时间稳定运行,有效避免了探测器的输出电压进入非线性区或饱和区.该探测装置可应用于连续变量量子密钥分发系统,有效降低由于量子态信号探测过程引入的额外噪声,提高系统的长期稳定性.Quantum key distributions,which could make legitimate communication parties Alice and Bob achieve the same random key with unconditional security,will have broad applications in defense,commerce,and communication.The protocol of the continuous variable quantum key distribution(CVQKD)has many advantages,such as easy preparation of the light source,high detector efficiency,and good compatibility with the classic fiber-optic communication systems.In recent years,great progress in the research of CVQKD has been made both theoretically and experimentally.In the protocol,the quadratures of the optical field with Gaussian or Non-Gaussian modulation are employed as the carriers of the key.The quadratures of the pulsed optical quantum states in CVQKD can be detected with a time-domain pulsed homodyne detector.The performance of the detector has great influences on the excess noises and the safe key rate of the quantum communication system.The measurement accuracy,which depends crucially on the common mode rejection ratio and the long-term stability,is the key performance of the detector.In order to improve the accuracy of measurement and avoid saturating the detector,we propose and demonstrate a technique to balance the two output beams of a 50/50 fiber coupler of the homodyne detector automatically.The auto-balance technique,which improves the long-term stability and high common mode rejection ratio,is described in the following.Firstly,the relation between the balance degree and the measurement accuracy is theoretically analyzed in detail.The result shows that a balance degree larger than 10^-4should be reached to ensure a high precision measurement when the intensity of the local oscillator pulse is 108 photons per pulse.Secondly,a fiber-based variable attenuator based on computer-controlled linear stepper motor is designed.The linear stepper motor that is used to drive the fiber coils has a small dimension of 20 cm × 20 cm × 28 cm and a minimum step size of 78 nm,and is controlled through the I/O port of a multi

关 键 词:连续变量量子密钥分发 时域平衡零拍探测器 自动平衡控制 

分 类 号:O413[理学—理论物理] TN918[理学—物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象