An 8.12 μW wavelet denoising chip for PPG detection and portable heart rate monitoring in 0.18 μm CMOS  被引量:1

An 8.12 μW wavelet denoising chip for PPG detection and portable heart rate monitoring in 0.18 μm CMOS

在线阅读下载全文

作  者:李响 张旭 李鹏 胡晓晖 陈弘达 

机构地区:[1]State Key Laboratory on Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China [2]National Defence University PLA China, Beijing 100091, China

出  处:《Journal of Semiconductors》2016年第5期104-109,共6页半导体学报(英文版)

摘  要:A low power wavelet denoising chip for photoplethysmography (PPG) detection and portable heart rate monitoring is presented. To eliminate noise and improve detection accuracy, Harr wavelet (HWT) is chosen as the processing tool. An optimized finite impulse response structure is proposed to lower the computational complexity of proposed algorithm, which is benefit for reducing the power consumption of proposed chip. The modulus max- ima pair location module is design to accurately locate the PPG peaks. A clock control unit is designed to further reduce the power consumption of the proposed chip. Fabricated with the 0.18μm N-well CMOS 1P6M technol- ogy, the power consumption of proposed chip is only 8.12μW in 1 V voltage supply. Validated with PPG signals in multiparameter intelligent monitoring in intensive care databases and signals acquired by the wrist photoelectric volume detection front end, the proposed chip can accurately detect PPG signals. The average sensitivity and positive prediction are 99.91% and 100%, respectively.A low power wavelet denoising chip for photoplethysmography (PPG) detection and portable heart rate monitoring is presented. To eliminate noise and improve detection accuracy, Harr wavelet (HWT) is chosen as the processing tool. An optimized finite impulse response structure is proposed to lower the computational complexity of proposed algorithm, which is benefit for reducing the power consumption of proposed chip. The modulus max- ima pair location module is design to accurately locate the PPG peaks. A clock control unit is designed to further reduce the power consumption of the proposed chip. Fabricated with the 0.18μm N-well CMOS 1P6M technol- ogy, the power consumption of proposed chip is only 8.12μW in 1 V voltage supply. Validated with PPG signals in multiparameter intelligent monitoring in intensive care databases and signals acquired by the wrist photoelectric volume detection front end, the proposed chip can accurately detect PPG signals. The average sensitivity and positive prediction are 99.91% and 100%, respectively.

关 键 词:low power wavelet denosing PPG detection portable heart rate monitoring 

分 类 号:R540.4[医药卫生—心血管疾病] TN432[医药卫生—内科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象