风力发电机组叶片连接高强螺栓的断裂原因分析  被引量:10

Causes Analysis on Fracture of High-strength Bolts for Fastening Wind Turbine Blades

在线阅读下载全文

作  者:姚兵印[1] 张志博[1] 马剑民[1] 王玉兴[1] 卢正欣[2] 

机构地区:[1]西安热工研究院有限公司,西安710032 [2]西安理工大学,西安710048

出  处:《理化检验(物理分册)》2016年第5期339-344,共6页Physical Testing and Chemical Analysis(Part A:Physical Testing)

摘  要:某风电场多台3MW风力发电机组在运行1.5a(年)后,叶片连接螺栓频繁发生断裂。通过化学成分分析、力学性能测试、金相分析及断口分析等方法,对其中一台风力发电机组的叶片连接螺栓断裂原因进行了分析。结果表明:该风电场叶片连接螺栓的断裂原因主要是材料中存在大量的氧化硅夹杂物,以及制造过程中热处理工艺控制不当导致的晶粒粗大等原因。且叶片连接螺栓安装及定期维护时预紧力分散度较大,使得螺栓在运行中受到复杂的应力条件下发生疲劳断裂失效。The high-strength bolts,which were applied to the 3 MW Wind turbine blades in a wind power plant,were fractured frequently after running for 1.5years.The reasons of the fracture were analyzed by means of chemical composition analysis,mechanical properties testing,metallographic analysis,fracture surface analysis,and so on.The results show that the main reasons of the fracture of the bolts were lots of silicon oxide inclusions in the material,bulky grains caused by improper heat treatment,and so on.In addition,the pretightening force was relatively dispersive in the installation and maintenance process,which led to fatigue fracture failure of the bolts under the complicated stress.

关 键 词:风电场 叶片 高强螺栓 疲劳断裂 

分 类 号:TG115.2[金属学及工艺—物理冶金] TG142.1[金属学及工艺—金属学]

 