酒—湖线对湖南电网变压器的直流偏磁影响研究  被引量:3

Research on the effects of Jiu—Hu HVDC project on transformer DC bias in Hunan power grid

在线阅读下载全文

作  者:岳一石[1] 周年光[1] 邹妍晖[1] 叶会生[1] 刘味果[1] 巢亚锋[1] 

机构地区:[1]国网湖南省电力公司电力科学研究院,湖南长沙410007

出  处:《湖南电力》2016年第3期5-8,共4页Hunan Electric Power

摘  要:为分析酒—湖特高压直流输电工程产生的直流偏磁对湖南电网的影响,本文基于场路耦合方法,建立湖南交流电网直流电流分布模型,实测获得湖南地区典型土壤电阻模型;通过建立测试模型,验证建模方法的有效性;计算直流接地极注入5 000 A入地电流后湖南电网220kV及以上变电站的直流偏磁情况,并对计算结果进行讨论。In order to analyze DC bias problem generated by Jiu—Hu HVDC project,based on field-circuit coupling method,direct current distribution model of Hunan AC power grid is established and typical soil resistance model in Hunan is acquired by measuring. The effectiveness of modeling method is verified through test model. The DC magnetic bias condition of substations on 220kV or above in Hunan power grid by injecting 5000 A DC current through DC grounding electrode is calculated and the results are analyzed and discussed.

关 键 词:特高压直流输电 直流偏磁 变压器 湖南电网 土壤电阻率 

分 类 号:TM72[电气工程—电力系统及自动化]

 