检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]河北科技大学机械工程学院,河北石家庄050018
出 处:《河北工业科技》2016年第4期333-336,共4页Hebei Journal of Industrial Science and Technology
摘 要:为实现设备出厂后毛细管组件可以根据现场工况阶梯调节,保证每台空调器工作性能达到最优,开发一种新型阶梯可调毛细管组件。对毛细管组进行了优化组合,确定了毛细管组件的尺寸。实验测得基于阶梯可调毛细管组件的2匹小型地源热泵在不同工况下的制热量与COP,较同型号的单一毛细管机组的制热量和COP最高可提高15%。A new kind of step-adjustment capillary component is developed, which can realize step adjustment according to the filed condition and ensure that every manufactured air-conditioner is in optimum state. The capillary components are optimized, and the sizes capillary components are determined. Through experiment, the heating capacity and COP of the step-adjustment capillary components based 2 hp small-scale ground source heat pump are obtained under different conditions, which are at mos t 15 percent higher than those of a single capillary unit.
关 键 词:供热与供燃气工程 阶梯可调 小型地源热泵 毛细管 组件